Laser beam fired during framing or when laser head is moving between patterns
1. Open RDWorks.
2. Access the user parameter interface.
3. Check that “Go scale mode” is set to “Close laser”(as shown).
If that parameter has been rightly set all the time
- Initiate framing again.
- Check whether the laser signal on the ammeter reads on or off.
- If it reads off, replace the laser power supply with a new, identical one.
- if it reads on, open the left glass cover (refer to the video)
- Measure the voltage between the L-on and GND terminals (as shown). The normal reading is 5V.
- If the voltage reads lower than 5V, replace the main board with a new, identical one. If the voltage reads 5V, replace the laser power supply.