Laser power LCD display not lit
If the entire machine is not powered on, follow the troubleshooting procedure ‘Machine not powered on >>’.
If any other component is powered on, but the laser power LCD is not, follow the steps below for troubleshooting:
- Open the control box cover and check that the laser power supply indicator is lit.
- If not, measure the input voltage of it (as shown).
- Voltage is normally 110V AC.
-
- If the multimeter reads 0, the key switch may be faulty.
If the multimeter reads 110, the laser power supply is faulty.
- If the multimeter reads 0, the key switch may be faulty.
2. If the laser power supply lights up but the LCD does not, replace the LCD with a new one.
Comments
0 comments
Please sign in to leave a comment.