Main board not energized(Split Fiber Laser Marker)
The problem might be with any of the following:
-
- Main power cable
- Wall socket
- EMI filter
- Emergency stop
- 5V power supply
- Remove the cover of the control box.
- Check the input voltage of the 5V power supply. If you are getting a reading and the indicator light on the power supply is not lit, replace the 5V power supply with a new, identical one.
- If you are getting no reading, go on to check the input and output voltage of the EMI filter.
- If you are getting an input reading and no output reading, replace the EMI filter with a new, identical one.
- If you are getting an input reading and an output reading, replace the emergency stop with a new, identical one.
- If no input reading can be read, check whether the wall socket that the machine is connected to has power.