Abnormal workbed movement during autofocusing
If the workbed keeps rising,
- Access the diagnostic interface from the control panel (as shown in the figure),
- Manually activate the laser head's autofocus sensor by pushing up the laser head.
- Check whether the corresponding interface on the panel is responsive. For models with KT332 board, the box before "LmtU-" will be filled with green if the sensor is working; for models with RD6442 board, the box will be filled with red.
If it is, check the auto-focus sensor wiring or replace the auto-focus sensor.
If it is not,
- In RDWorks, access "Vendor param".
- Adjust the Z (or U) axis "home offset" (as shown).
If the workbed keeps lowering, check the auto-focus sensor wiring or replace the auto-focus sensor.
If the panel displays "autofocus disabled",
- In RDWorks, access user parameters.
- Enable "autofocus" (as shown).
If the workbed lowers to a wrong focal length during autofocusing,
- In RDWorks, access user parameters.
- Adjust the value of the Z(or U) axis "home offset" (as shown before).
Comments
0 comments
Please sign in to leave a comment.